• Users Online: 213
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2017  |  Volume : 20  |  Issue : 2  |  Page : 166-170

Accuracy of clinical and ultrasound examination of palpable breast lesions in a resource-poor society


1 Department of Radiology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Nigeria
2 Department of General Surgery, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Nigeria
3 Department of Histopathology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Nigeria

Correspondence Address:
Uzoamaka R Ebubedike
Department of Radiology, Nnamdi Azikiwe University Teaching Hospital, Nnewi
Nigeria
Login to access the Email id


DOI: 10.4103/tjmr.tjmr_60_16

Rights and Permissions

Background: Palpable breast masses are common presentations in resource-poor societies. Clinical and ultrasonographic breast examinations are commonly available means of evaluation. Objective: The objective of this study was to compare the accuracy of clinical breast examination (CBE) and ultrasonography in the diagnosis of palpable breast masses. Methodology: Consenting females presenting with palpable breast masses at the general surgical outpatient clinic were assessed clinically by the most senior surgeon, ultrasonographically by two radiologists, and the diagnosis compared with histologic examination. Results: One hundred and thirteen patients were recruited during the study period from January 2013 to April 2014. Of these, 53 patients (46.9%) had breast core biopsy, while 60 (53.1%) had open surgical biopsy. Only 67 (59.3%) patients had their histological results available. The mean age was 41.58 years (range 16–78). CBE achieved a sensitivity of 82.1%, specificity 67.9%, positive predictive value (PPV) 78%, negative predictive value 73%, overall accuracy 76.1%, false positive rate 32.1%, and false negative rate 17.9%. Breast ultrasonography had a sensitivity of 86.8%, specificity 72.4%, PPV 80.5%, negative predictive value 80.8%, overall accuracy 80.6%, false positive rate 27.6%, and false negative rate 13.2%. Conclusion: This study revealed no statistical significant difference between the accuracy of CBE and breast ultrasonography. We recommend that both should be used in the evaluation of palpable breast masses.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed515    
    Printed16    
    Emailed0    
    PDF Downloaded73    
    Comments [Add]    

Recommend this journal